Charging and Discharging Devices of the Battery
Author: Source:   Date:2016-12-08 

 

1.Main Function

Having  the function of monitoring and constant-current dischargeat the same time.

Can be completely discharged: accurately obtain the capacity of battery.

Can be dischargedin a short time: each daycapacity and internal resistance of each battery of the whole group are analyzed for 5-10 minutes 

With detection function (option) for external current : to detect the state of external charger and have the function of floating monitoring .

With record function in floating time: can record the status of the battery in a floating, (must be equipped with external battery detector).

With function of intelligent scan cycle: according to need to set a variety of different scan cycle  to obtain the complete test data.

External contact function: provide output contact for complete discharge, external charging too high or other alarm to treat appropriately for charging equipment or other devices .

Have many alarm functions: can timely alarm, and stop the discharge.

Have many alarm functions: can timely alarm, and stop the discharge.

With functions of software analysis:can storage and analyze the test data , display the total voltage graph ,current graph, single voltage bar chart, feature comparison chart, monomer voltage curve, capacity analysis table and discharge form, automatically print test reports, and generate EXCEL sheet format.

2.Product features

Host built-in memory, read storage records with U disk, and do not need to carry the computer, single machine can work; you can use a computer to print the report in the future.

Safety device: safety device is controlled to start by microcomputer , when there is the alarm, it can completely isolate battery to make it not be affected.

Using highly efficient discharge components:when discharging, load has not red-hot phenomenon; Even if the cooling fan is stopped, electric heating element automatically reduce the discharge current, there will be no general discharge device of red-hot dangerous phenomenon usually.

With voltage and current calibration correction function, it can adjust and correct for the measurements of instrument at any time to guarantee the accuracy of measurement.

It has positive and negative cable meter function to avoid negative level reversed and cause a short-circuit.

It has memory function when power supply drops. All test data is not lost after power off, and continue to work after the electricity to prevent accidental power influenting to obtain the complete test results.

Appearance: design with both hands makes solid and reliable. Panel adopts positive inclined plate design to make easily read,operate ,beautiful and generous. Design connection in the front, a cooling fan blow back.

Using the FLASH ROM memory storage capacity: can be up to 10 years. There will be no phenomenon with memory providing battery failure and leakage.

 

Standard specifications